P4: CRITICAL fix — level = am/res (not am*res); fc-resonance shape now correct
...
res=|2B/A| is minimal at band centre (not maximal). Model uses xv=log10(A_k/res_k)
=> level = am / res. Old am*res inverted the fc-response (cut more off-center).
Fixed; fc-scan (tone1kq, band fc 800..1200 via t1kq_only1_<fc>) now tracks the
reference: scale=42 mean|err| 2.46 dB, intact shape (deepest at fc==tone). Was
flat+inverted before. Remaining under-cut off-center -> FFT-conv smoothing/gaps.
2026-08-20 16:25:00 +03:00
..
2026-08-20 15:10:29 +03:00
2026-08-17 11:25:35 +03:00
2026-08-17 20:02:32 +03:00
2026-08-17 15:49:48 +03:00
2026-08-19 22:48:32 +03:00
2026-08-17 11:25:35 +03:00
2026-08-17 11:25:35 +03:00
2026-08-20 02:25:59 +03:00
2026-08-20 02:25:59 +03:00
2026-08-17 20:02:32 +03:00
2026-08-17 11:25:35 +03:00
2026-08-19 23:25:21 +03:00
2026-08-19 23:25:21 +03:00
2026-08-19 23:25:21 +03:00
2026-08-17 11:25:35 +03:00
2026-08-17 11:25:35 +03:00
2026-08-20 16:25:00 +03:00
2026-08-20 16:14:50 +03:00
2026-08-20 13:11:27 +03:00
2026-08-18 17:08:42 +03:00
2026-08-18 17:08:42 +03:00
2026-08-20 10:41:24 +03:00
2026-08-20 01:30:33 +03:00
2026-08-20 09:26:38 +03:00
2026-08-20 01:30:33 +03:00
2026-08-20 01:12:12 +03:00
2026-08-20 01:12:12 +03:00
2026-08-19 23:53:01 +03:00
2026-08-19 23:53:01 +03:00
2026-08-17 11:25:35 +03:00
2026-08-19 22:00:14 +03:00
2026-08-17 11:25:35 +03:00
2026-08-17 11:25:35 +03:00
2026-08-19 22:00:22 +03:00
2026-08-20 15:10:29 +03:00
2026-08-20 15:00:53 +03:00
2026-08-20 13:11:27 +03:00
2026-08-20 13:11:27 +03:00
2026-08-17 18:39:50 +03:00
2026-08-20 10:41:24 +03:00
2026-08-20 10:41:24 +03:00
2026-08-19 22:48:32 +03:00
2026-08-19 22:48:32 +03:00
2026-08-17 11:25:35 +03:00
2026-08-17 11:25:35 +03:00
2026-08-17 18:39:50 +03:00
2026-08-18 17:08:42 +03:00
2026-08-19 22:00:22 +03:00
2026-08-19 22:00:22 +03:00
2026-08-20 07:12:56 +03:00
2026-08-20 07:12:56 +03:00
2026-08-20 07:12:56 +03:00